Automated analysis of pectoralis major thickness in pec-fly exercises: evolving from manual measurement to deep learning techniques

Abstract

This study addresses a limitation of prior research on pectoralis major (PMaj) thickness changes during the pectoralis fly exercise using a wearable ultrasound imaging setup. Although previous studies used manual measurement and subjective evaluation, it is important to acknowledge the subsequent limitations of automating widespread applications. We then employed a deep learning model for image segmentation and automated measurement to solve the problem and study the additional quantitative supplementary information that could be provided. Our results revealed increased PMaj thickness changes in the coronal plane within the probe detection region when real-time ultrasound imaging (RUSI) visual biofeedback was incorporated, regardless of load intensity (50% or 80% of one-repetition maximum). Additionally, participants showed uniform thickness changes in the PMaj in response to enhanced RUSI biofeedback. Notably, the differences in PMaj thickness changes between load intensities were reduced by RUSI biofeedback, suggesting altered muscle activation strategies. We identified the optimal measurement location for the maximal PMaj thickness close to the rib end and emphasized the lightweight applicability of our model for fitness training and muscle assessment. Further studies can refine load intensities, investigate diverse parameters, and employ different network models to enhance accuracy. This study contributes to our understanding of the effects of muscle physiology and exercise training.

Introduction

Skeletal muscle training is crucial for enhancing athletic performance and the overall quality of life [1,2,3,4]. Real-time visual biofeedback, particularly real-time ultrasound imaging (RUSI), has made significant progress in sports medicine and rehabilitation. It provides non-invasive, instantaneous, and detailed insights into the human body [5,6,7]. RUSI, a type of visual biofeedback, is exceptionally useful for real-time monitoring of skeletal muscles [8,9,10]. For example, Henry and Westervelt [6] demonstrated in their research that abdominal contraction training is more effective when supplemented with RUSI visual biofeedback.

Our team recently developed a portable ultrasonography-based RUSI visual biofeedback system for pectoralis major (PMaj) exercises (pec-fly) in a cohort of 25 athletes [9]. The system significantly enhanced the PMaj exercise effectiveness, as revealed by the RUSI probe in the area between the third intercostal space and the midclavicular line on the left side (Fig. 1a). However, the thickness measurement procedure still involves manual operations [9], such as manually selecting both the location and line segment for thickness determination.

Fig. 1
figure 1

Experiment setup for probe location and data processing. a Schematic diagram of the experiment [11]; b Left, proposed probe placement in the anatomy: the red cross indicates the probe location. Right, representative ultrasound frames of PMaj, two frames represent the start frame and end frame (scanning depth is 55 mm and each small segment is 5 mm). The ground truth with manually labeled highlights

Advancements in deep learning have improved the automatic extraction of tissue contours using ultrasound imagery. Examples include the UNet model proposed by Ronneberger et al. [12], breast ultrasound image segmentation with an extended UNet architecture proposed by Guo et al. [13], multiscale feature-aggregated UNet for intravascular ultrasound image segmentation by Xia et al. [14], and recent advancements in ultrasound image segmentation using the transformer model [15,16,17,18]. Despite recent developments, the UNet model is still preferred because of its lightweight deployment capabilities [19].

This study aimed to develop a portable and lightweight ultrasound-based RUSI biofeedback system. To achieve this, we propose using a deep learning model for frame-by-frame segmentation of the ultrasound image stream. This method promises automated and precise analysis of PMaj thickness variations, offering a detailed view of changes in the coronal plane that could improve the intelligence and efficiency of current systems [9]. In addition, this study can clarify or confirm certain phenomena in biomedical research by examining variations in PMaj thickness.

The remainder of this paper is organized as follows. Methods section  firstly outlines the material used in this study, including system specifications, diagnostic data, and data volumes; secondly a comprehensive exposition of the deep learning models employed is presented, delineating the motion estimation and image segmentation branches thirdly, we elaborate on our methodology for evaluating the PMaj thickness of segmentation results and discuss the findings therein; finally, we evaluate modifications applied to the model, including disintegration experiments performed on the RNN components and enhancements made to the UNet network. Results section  presents the results, highlighting the model’s optimization and performance evaluations, coupled with comparative analyses of diverse model outcomes. In Discussion section, a comprehensive analysis is conducted to assess the variances in thickness among different condition groups, along with the changes across different measurement locations of the maximum thickness. Finally, we engage in a discussion of our research findings and their potential physiological significance.

Methods

Materials

The RUSI biofeedback system and its training configuration are illustrated in Fig. 2. This system comprises two main components: (a) a bespoke ultrasound image-acquisition unit and (b) a mobile terminal (Fig. 1). Specifically, the image acquisition unit includes a custom-designed ultrasound probe measuring 4.5 cm × 0.7 cm, a signal cable, and a control box with dimensions of 15.6 cm × 6 cm × 2 cm. The weight of the probe is approximately 350 g, making it lightweight and easily maneuverable during operation. Operating at an ultrasound frequency of 7.5 MHz with a 35% bandwidth, the probe is appropriate for superficial muscle imaging based on previous research [8]. Its scanning depth ranges from 20 mm to 55 mm, allowing for versatile applications across various muscle groups and anatomical structures. The control box contains the components for signal processing and data transmission. This unit utilizes 5G Wi-Fi technology for seamless transmission of ultrasound images between the ultrasound probe and the mobile terminal, ensuring a stable connection with a theoretical maximum speed of 450 Mbps. This high-speed connection, coupled with the system’s support for the 802.11 g Wi-Fi standard operating at a 20 MHz frequency, provides reliable data transmission while maintaining compatibility with modern smartphone devices. An application installed on a smartphone displayed these B-mode ultrasound images, with the system achieving 18 frames per second.

Fig. 2
figure 2

Wearable RUSI biofeedback system: ultrasound image acquisition unit wirelessly connected to the matched smartphone-based application

The experimental design and participant selection criteria used in our research were based on previous methodologies [9]. We enrolled 25 healthy young men and used a repeated measures design. The inclusion criteria for the study were as follows: individuals without a history of chest, spine, or upper limb surgery; those who have not faced recent orthopedic or neurological issues; participants without significant chronic medical conditions; and subjects with no previous experience in RUSI feedback training. Additionally, the participants were required to refrain from any upper-body resistance training for a minimum of 48 h before the experiment. The subjects were aged from 18 to 35 years. Before the study, the participants were thoroughly informed of the objectives and procedures of the experiment. All participants were required to sign a consent form. This study received ethical approval from the Hong Kong Polytechnic University Ethical Review Board (No. HSEARS 20180418002).

A meticulous image labeling process was performed to enable comprehensive and automated measurement of the PMaj thickness in the coronal plane within the detection area of the probe. This approach effectively overcomes the limitations associated with previous manual measurement methods for the number of processable images and measurement locations. Under the guidance of a medical professional, the labelers used the Labelme image annotation tool [20] to annotate the selected frames from the PMaj ultrasound video. The annotations focused on the contour of the PMaj muscle within the probe detection region in the coronal plane, including the start and end frames (Fig. 1b). The resulting dataset comprised 13,640 images and 1,136 annotations.

Proposed model

Our approach utilizes a deep-learning model to measure the PMaj thickness of the processed data (Fig. 3). The model employs a deep learning optical flow motion estimation model to detect motion patterns and applies these findings to motion compensation and artifact removal in medical imaging. In addition, a segmentation model was employed to isolate and analyze features from the designated regions. Our methodology resulted in a joint learning approach that combined the outputs of both the motion estimation and segmentation models. The details of each branch are as follows:

  1. (1)

    The Siamese-style multiscale recurrent motion estimation branch (based on the work proposed by Qin et al. [21]). In our implementation, we replace the recurrent neural network (RNN) [22] component with two convolutional layers.

  2. (2)

    For the segmentation branch, we employed a UNet segmentation network. Unlike the approach proposed by Qin et al. [21], in which the weights were shared, we treated the motion estimation results as the ground truth for segmentation. This is complemented by adopting a deep supervision strategy to ensure the preservation of multiscale information in the segmentation results.

Fig. 3
figure 3

Deep learning models were used in this research. The model is comprised of a motion estimation branch and an image segmentation branch

The effectiveness of this integration was measured using the Dice coefficients from Eq. (1) as the key performance metric [21]. To guarantee the stability and reliability of the results, a fivefold cross-validation method was implemented.

$$\begin{array}{c}Dice=\frac{\left|Y\cap P\right|}{\left|Y\right|\cup \left|P\right|}\end{array}$$
(1)

where Y denotes the ground truth and P denotes the model output.

Methodology for PMaj thickness measurement

The experimental protocol used in this study was based on the methodology established in our previous manual measurement studies [9]. The complete training protocol is illustrated in Fig. 4. Data collection included exercises under varying load conditions, specifically low-moderate and high loads. These values were quantified as 50% and 80% of the one-repetition maximum (1-RM) [23], respectively. For each intensity level, the participants performed the pec-fly exercise twice, once without RUSI biofeedback, and once with RUSI biofeedback. Before the experimental sessions, we recorded the baseline thickness of the PMaj in a relaxed state without any resistance. Our approach differs from traditional methods that visually estimate the PMaj thickness by identifying the point of maximum distance between the inferior border tip and superior border-bottom. Rather, we utilized an automated system to calculate the PMaj thickness throughout the probe detection region. This method enhances the accuracy and comprehensiveness of the measurements. Muscle activation levels were measured using the muscle thickness change (%) [24,25,26,27,28]. This was defined as the percentage difference in PMaj thickness between the resting state and maximum contraction and was calculated using Eq. (2).

Fig. 4
figure 4

Method outline: Participants were instructed to remain still for approximately 30 s to establish a baseline assessment. This was followed by four experimental conditions of PMaj resistance training. The training session consisted of two assigned load training intensities (50% of 1-RM and 80% of 1-RM), with the conditions without RUSI biofeedback continuously being performed before the condition with RUSI biofeedback. One set of three repetitions was performed in each experimental condition. Our methodology employs a comprehensive automated approach for calculating PMaj thickness across the entire probe detection region (scanning depth is 55 mm and each small segment is 5 mm), in contrast to manual measurement methods [9]

$$\begin{array}{c}Muscle thickness-change \left(\mathrm{\%}\right)=\\ \frac{Maximally contracted thickness-Resting thickness}{Resting thickness}\times 100\%\end{array}$$
(2)

Evaluating model modifications: an ablation study

We conducted ablation experiments on the key components of a deep learning model to validate the effectiveness of our modifications. We focused on two main aspects: modifying the RNN component in the motion estimation branch and applying the UNet network in the segmentation branch.

The transition from RNN to convolutional layers: In the motion estimation branch, as detailed in Fig. 3, the original RNN component was replaced with two convolutional layers. We evaluated the impact of this change by comparing the model’s parameter count and performance in both the original and modified states. The performance evaluation focused on the accuracy of the model in capturing motion patterns and compensating for motion for medical image processing.

We employ a UNet network in the segmentation branch, diverging from the weight-sharing scheme proposed by Qin et al. [21]. We used the motion estimation outcomes as ground-truth data for segmentation, incorporating a deep supervision approach to preserve multiscale information in the segmentation results. To establish the superiority of the UNet network, we compared it with UNet++ [29] and the latest EGE-UNet [30] in terms of the parameter count and model performance.

The ablation experiments were designed to precisely quantify the contribution of each modification to the overall model performance. These experiments were designed to validate the effectiveness of the proposed model for measuring PMaj thickness, confirming the stability and reliability of the results using fivefold cross-validation.

Results

To optimize the model, we replaced the RNN component with a two-layer convolutional neural network (CNN). This modification aimed to assess whether a simpler and more computationally efficient architecture could maintain or enhance the model performance. The comparison results are presented in Table 1. While the two-layer CNN model improved computational efficiency, it showed a minor reduction in motion estimation accuracy. This outcome suggests that while simplification of the model architecture can lead to faster processing times, it may reduce the precision in certain aspects of performance.

Table 1 Performance comparison of RNN and two-layer CNN models

A comparative analysis of UNet, UNet++ , and EGE-UNet revealed that each model had similar segmentation effectiveness, as reflected by their Dice coefficients. However, variations were noted in their BCEFocalLoss performances, with EGE-UNet scoring the highest, suggesting potential limitations when generalizing new datasets. UNet++ features dense convolutional blocks and deep supervision, enhancing feature extraction and learning accuracy but at the cost of increased parameters. In contrast, while EGE-UNet prioritizes parameter efficiency, it achieves a halved parameter count without a proportional gain in computational speed. Therefore, UNet emerged as a balanced choice for our segmentation requirements because of its optimal blend of complexity and efficiency. Further details are presented in Table 2.

Table 2 Comparative analysis of UNet, UNet++ , and EGE-UNet

In this study, we chose a combination of a two-layer CNN and UNet as the appropriate model. This was to ensure an optimal balance between maintaining a swift response speed and achieving high model performance. The integration of a two-layer CNN with UNet provided a computationally efficient model that captured the detailed features necessary for accurate segmentation. This combination was effective and did not compromise the rapid processing capabilities required for our analysis.

The performance of the tailored model was evaluated. By training the proposed model, we achieved an average Dice coefficient of 0.94 across each fold of the optimal model. We calculated the change in the PMaj thickness within the probe detection region (located at the intersection of the third intercostal space and the midclavicular line on the left side of the body) under various experimental scenarios using Eq. (2). The study included training intensities at low-moderate (50% of 1-RM) and high (80% of 1-RM) loads, each further categorized based on the pec-fly exercise performed with or without RUSI biofeedback. Additionally, we documented the PMaj thickness at rest, which was denoted as the resting group. Line graphs were used to depict the PMaj thickness change trends, providing visualizing the variations across different load intensities and biofeedback conditions (with and without biofeedback) at each specified load intensity.

Previous research [9] demonstrated the effectiveness of RUSI visual biofeedback in enhancing PMaj thickness changes through manual measurements at manually selected locations. Our study expands on this using automated measurements to cover the entire transverse region of the PMaj thickness change in the probe-detection region. This study examined the impact of RUSI visual biofeedback on changes in the thickness of the entire transverse region of the PMaj in the probe detection region at two different training intensities. The results are shown in Fig. 5.

Fig. 5
figure 5

PMaj thickness change for the same load training intensity at two different biofeedback conditions (with and without RUSI biofeedback) (n = 25). In graphs, the curves represent the average values of the PMaj thickness change, while the envelope areas represent the standard deviation of the PMaj thickness change. (a) represents the PMaj thickness change with different biofeedback conditions at the low-moderate load training intensity (50% of 1-RM); (b) represents the PMaj thickness change with different biofeedback conditions at the high load training intensity (80% of 1-RM). For the assigned load training intensity with RUSI biofeedback (on), the PMaj thickness change was significantly increased for low-moderate training intensity as well as for high-intensity training compared to the corresponding load training intensity without RUSI biofeedback (off). This emphasizes the important role of RUSI visual biofeedback in the process of muscle thickness change

After receiving RUSI biofeedback, the PMaj thickness increased at both training intensities (n = 25). Figure 5 shows that the standard deviations of the PMaj thickness change are significantly larger on the right-hand side of the graphs. However, the average values of PMaj thickness change were not significantly different between the two intensities.

Furthermore, we analyzed PMaj thickness variations at different load training intensities within the same biofeedback condition. The findings presented in Fig. 6 reveal that without RUSI biofeedback, PMaj thickness changes were more pronounced at 80% 1-RM than at 50% 1-RM, particularly in the middle part of Fig. 6a, with less variation at the ends. In contrast, with RUSI biofeedback, the differences in PMaj thickness changes between the two intensities were less distinct, as shown in Fig. 6b. In other words, the data distribution in Fig. 6b does not exhibit the corresponding characteristics (larger differences in the middle part of the graph and smaller differences at both ends) in Fig. 6a.

Fig. 6
figure 6

PMaj thickness change for two different load training intensities at the same biofeedback condition (with or without RUSI biofeedback) (n = 25). The curves represent the average values of the PMaj thickness change, while the envelope areas represent the standard deviation of the PMaj thickness change. (a) represents PMaj thickness change without RUSI biofeedback at different load training intensities; (b) represents PMaj thickness change with RUSI biofeedback at different load training intensities. It is shown in (a) and (b) that differences in the PMaj thickness change distribution between them

Finally, we review the data analysis of a previous study on the selection and measurement of the maximum thickness of the PMaj. To objectively determine the optimal site for measuring peak PMaj thickness, our goal was to pinpoint the location where PMaj thickness is at its maximum. We revisited the data analysis method used in a previous study to determine the maximum thickness change in PMaj under different experimental conditions [9]. Considering the potential impact of boundary effects during image processing [31] that may result from overly narrow spacing, we subdivided the region into five equidistant intervals as much as possible, as illustrated in Fig. 7.

Fig. 7
figure 7

Distribution of the measurement locations of the PMaj maximum thickness change for different experimental conditions (n = 25). (a) represents the 50% of 1-RM without RUSI biofeedback; (b) represents the 50% of 1-RM with RUSI biofeedback; (c) represents the 80% of 1-RM without RUSI biofeedback; (d) represents the 80% of 1-RM with RUSI biofeedback. We found that the PMaj maximum thickness occurrences had the highest ratio within the rightmost interval of the graph

The analysis shows that the maximum thickness change in PMaj was mostly located in the rightmost interval of Fig. 7 under various experimental conditions. This suggests that the measurement locations for the maximal change in PMaj thickness were frequently closer to the rib end on the left side of the body. Differences in experimental procedures or individual participant characteristics could account for variations in PMaj thickness at other locations.

In general, our research confirmed the significant impact of RUSI biofeedback on PMaj exercises based on previous studies [9]. The observations were broadened to cover the entire probe detection area. We discovered that training with wearable RUSI biofeedback devices at 50% and 80% 1-RM loads significantly increased the PMaj thickness compared with training without these devices.

Additionally, we observed notable differences in the PMaj thickness changes between 50% and 80% of the 1-RM loads when conducted without RUSI biofeedback. These variations were less distinct when the RUSI biofeedback was used. Furthermore, the maximum thickness change in PMaj was predominantly observed near the rib end on the left side within the detection area, specifically in the rightmost interval (Fig. 7). These findings highlight the impact of RUSI biofeedback on changes in PMaj thickness and improve our understanding of its role in muscle training. This will contribute to more precise and effective training guidelines for practical applications.

Discussion

To address the limitations of subjective manual measurements in previous research [9], we utilized a deep learning model to segment the ultrasound images and calculate the PMaj thickness. The segmentation results of the model achieved a DSC of 0.938 ± 0.033, achieving acceptable accuracy and reliability. This method could improve the flexibility and convenience of wearable RUSI systems for real-time monitoring and facilitate a thorough and quantitative analysis of the entire probe detection region.

First, our findings showed an increase in the PMaj thickness in the coronal plane with the incorporation of RUSI visual biofeedback, regardless of training intensity. This aligns with prior research [9] and expands the measurement scope to include the entire probe detection region. After integrating RUSI biofeedback into the pec-fly exercises, we observed adaptive changes in PMaj thickness. The standard deviation was notably higher near the rib end than at the clavicular end (n = 25), indicating individual differences in PMaj thickness.

Second, significant variations in the PMaj thickness were observed between 50% and 80% of the 1-RM loads, particularly in the central region, with smaller differences towards the edges. These findings are objective and based on the data collected, without any subjective evaluations. These disparities were considerably reduced by the RUSI biofeedback, indicating a possible alteration in the muscle activation strategies of the participants. This phenomenon, potentially linked to different muscle contraction patterns, has been observed in other muscle training studies [32,33,34], and it may be linked to different muscle contraction patterns. Further investigation is warranted for the PMaj exercises.

Third, our study aimed to identify the optimal site for measuring the peak PMaj thickness based on prior data [9]. The results showed that the peak PMaj thickness measurements predominantly occurred near the rib end within the probe detection area, suggesting that this is the ideal location for such measurements. This insight could be utilized in future research to accurately determine the peak PMaj thickness measurement locations, particularly near the rib end.

In addition, our findings suggest that the division of training intensities into 50% and 80% 1-RM may have been inadequate, resulting in ambiguous data. Future studies should refine these intensities and collect more data to achieve a more accurate analysis of the RUSI biofeedback effects. Although this requires more data, using automated measurements reduces the additional processing time and cost.

Finally, our model is efficient and can function on a standard personal computer without requiring a GPU [35]. This makes it a practical addition to previously proposed portable ultrasound systems for fitness training [9]. Furthermore, we provided guidelines for accurately selecting measurement locations for the maximum thickness of PMaj within the detection area of the probe. Future studies should investigate the effects of various parameters and training methods on changes in the PMaj thickness during exercise. These findings enhance our understanding of muscle physiology and the effects of exercise training.

Conclusions

This study used a deep learning model to comprehensively analyze changes in PMaj thickness during pec-fly exercises using a wearable ultrasound imaging setup. We provide quantitative insights into PMaj thickness alterations in the coronal plane within the entire probe detection region, overcoming the limitations of manual measurements. We found that incorporating RUSI visual biofeedback resulted in augmented PMaj thickness changes, regardless of load intensity. Furthermore, biofeedback has been used to mitigate load-dependent differences, resulting in improved muscle activation strategies. The optimal site for measuring peak PMaj thickness near the rib end was pinpointed. While additional research is needed to fine-tune load intensities and improve segmentation techniques, our streamlined model provides valuable application in fitness training contexts. This study contributes to the understanding of muscle physiology and lays the foundation for exploring various training approaches.

Availability of data and materials

For access to the experimental data in this paper, please contact the corresponding authors Yongjin Zhou and Yongping Zheng.

Abbreviations

PMaj:

Pectoralis major

RUSI:

Real-time ultrasound imaging

1-RM:

One-repetition maximum

CNN:

Convolutional neural network

RNN:

Recurrent neural network

References

  1. Darter BJ, Wilken JM (2011) Gait training with virtual reality-based real-time feedback: improving gait performance following transfemoral amputation. Phys Ther 91(9):1385–1394. https://doi.org/10.2522/ptj.20100360

  2. Dong JP, Lee WN (2022) Noninvasive assessment of in vivo passive skeletal muscle mechanics as a composite material using biomedical ultrasound. IEEE Trans Biomed Eng 69(3):1162–1172. https://doi.org/10.1109/TBME.2021.3115144

    Article  Google Scholar 

  3. Lancere L, Jürgen M, Gapeyeva H (2023) Mixed reality and sensor real-time feedback to increase muscle engagement during deep core exercising. Virtual Reality 27(4):3435–3449. https://doi.org/10.1007/s10055-022-00726-3

    Article  Google Scholar 

  4. Lim OB, Kim JA, Song SJ, Cynn HS, Yi CH (2014) Effect of selective muscle training using visual EMG biofeedback on infraspinatus and posterior deltoid. J Hum Kinet 44:83–90. https://doi.org/10.2478/hukin-2014-0113

    Article  Google Scholar 

  5. Hides JA, Richardson CA, Jull GA (1998) Use of real-time ultrasound imaging for feedback in rehabilitation. Man Ther 3(3):125–131. https://doi.org/10.1016/S1356-689X(98)80002-7

    Article  Google Scholar 

  6. Henry SM, Westervelt KC (2005) The use of real-time ultrasound feedback in teaching abdominal hollowing exercises to healthy subjects. J Orthop Sports Phys Ther 35(6):338–345. https://doi.org/10.2519/jospt.2005.35.6.338

    Article  Google Scholar 

  7. Whittaker JL, Teyhen DS, Elliott JM, Cook K, Langevin HM, Dahl HH et al (2007) Rehabilitative ultrasound imaging: understanding the technology and its applications. J Orthop Sports Phys Ther 37(8):434–449. https://doi.org/10.2519/jospt.2007.2350

    Article  Google Scholar 

  8. Lin SS, Zhu B, Zheng YY, Huang GZ, Zeng Q, Wang CH (2021) Effect of real-time ultrasound imaging for biofeedback on trunk muscle contraction in healthy subjects: a preliminary study. BMC Musculoskelet Disord 22(1):142. https://doi.org/10.1186/s12891-021-04006-0

    Article  Google Scholar 

  9. Huang ZH, Ma CZH, Wang LK, Wang XY, Fu SN, Zheng YP (2022) Real-time visual biofeedback via wearable ultrasound imaging can enhance the muscle contraction training outcome of young adults. J Strength Cond Res 36(4):941–947. https://doi.org/10.1519/jsc.0000000000004230

    Article  Google Scholar 

  10. Sheng ZY, Iyer A, Sun ZY, Kim K, Sharma N (2022) A hybrid knee exoskeleton using real-time ultrasound-based muscle fatigue assessment. IEEE/ASME Trans Mechatron 27(4):1854–1862. https://doi.org/10.1109/TMECH.2022.3171086

    Article  Google Scholar 

  11. AlanSidebottom (2015) Tag Archives: cardiovascular examination. Osteopathicthoughts. https://osteopathicthoughts.wordpress.com/tag/cardiovascular-examination/. Accessed 4 Jan 2024

  12. Ronneberger O, Fischer P, Brox T (2015) U-Net: convolutional networks for biomedical image segmentation. In: Navab N, Hornegger J, Wells W, Frangi A (eds) Medical image computing and computer-assisted intervention-MICCAI 2015. 18th international conference, Munich, Germany, October 2015. Lecture notes in computer science (Image processing, computer vision, pattern recognition, and graphics), vol 9351. Springer, Cham, pp 234–241. https://doi.org/10.1007/978-3-319-24574-4_28

  13. Guo YJ, Duan XG, Wang CY, Guo HQ (2021) Segmentation and recognition of breast ultrasound images based on an expanded U-Net. PLoS One 16(6):e0253202. https://doi.org/10.1371/journal.pone.0253202

    Article  Google Scholar 

  14. Xia MH, Yan WJ, Huang Y, Guo Y, Zhou GH, Wang YY (2020) Extracting membrane borders in IVUS images using a multi-scale feature aggregated U-Net. In: Proceedings of the 42nd annual international conference of the IEEE engineering in medicine & biology society, IEEE, Montreal, 20-24 July 2020. https://doi.org/10.1109/EMBC44109.2020.9175970

  15. Ding WP, Wang HP, Huang JS, Ju HR, Geng Y, Lin CT et al (2023) FTransCNN: fusing transformer and a CNN based on fuzzy logic for uncertain medical image segmentation. Information Fusion 99:101880. https://doi.org/10.1016/j.inffus.2023.101880

    Article  Google Scholar 

  16. Bi H, Cai CJ, Sun JW, Jiang YB, Lu G, Shu HZ et al (2023) BPAT-UNet: boundary preserving assembled transformer UNet for ultrasound thyroid nodule segmentation. Comput Methods Programs Biomed 238:107614. https://doi.org/10.1016/j.cmpb.2023.107614

    Article  Google Scholar 

  17. He QQ, Yang QJ, Xie MH (2023) HCTNet: A hybrid CNN-transformer network for breast ultrasound image segmentation. Comput Biol Med 155:106629. https://doi.org/10.1016/j.compbiomed.2023.106629

    Article  Google Scholar 

  18. Xiao HG, Li L, Liu QY, Zhu XH, Zhang QH (2023) Transformers in medical image segmentation: a review. Biomed Signal Process Control 84:104791. https://doi.org/10.1016/j.bspc.2023.104791

    Article  Google Scholar 

  19. Vaze S, Xie WD, Namburete AIL (2020) Low-memory CNNs enabling real-time ultrasound segmentation towards mobile deployment. IEEE J Biomed Health Inform 24(4):1059–1069. https://doi.org/10.1109/JBHI.2019.2961264

    Article  Google Scholar 

  20. Wada K (2016) Labelme: Image Polygonal Annotation with Python. https://github.com/labelmeai/labelme. Accessed 9 March 2024

  21. Qin C, Bai WJ, Schlemper J, Petersen SE, Piechnik SK, Neubauer S et al (2018) Joint learning of motion estimation and segmentation for cardiac MR image sequences. In: Frangi A, Schnabel J, Davatzikos C, Alberola-López C, Fichtinger G (eds) Medical image computing and computer assisted intervention - MICCAI 2018. 21st international conference, Granada, Spain, September 2018. Lecture notes in computer science (Image processing, computer vision, pattern recognition, and graphics), vol 11071. Springer, Cham, pp 472–480. https://doi.org/10.1007/978-3-030-00934-2_53

  22. Wikipedia (2010) Long short-term memory. Wikipedia, The Free Encyclopedia. https://static.hlt.bme.hu/semantics/external/pages/LSTM/en.wikipedia.org/wiki/Long_short-term_memory.html. Accessed 15 Jan 2024

  23. National Strength and Conditioning Association, Baechle TR, Earle RW (2008) Essentials of strength training and conditioning. Human Kinetics, Champaign

  24. Kiesel KB, Uhl TL, Underwood FB, Rodd DW, Nitz AJ (2007) Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging. Man Ther 12(2):161–166. https://doi.org/10.1016/j.math.2006.06.011

    Article  Google Scholar 

  25. McMeeken JM, Beith ID, Newham DJ, Milligan P, Critchley DJ (2004) The relationship between EMG and change in thickness of transversus abdominis. Clin Biomech 19(4):337–342. https://doi.org/10.1016/j.clinbiomech.2004.01.007

    Article  Google Scholar 

  26. Latash ML (2018) Muscle coactivation: definitions, mechanisms, and functions. J Neurophysiol 120(1):88–104. https://doi.org/10.1152/jn.00084.2018

    Article  Google Scholar 

  27. ShahAli S, Shanbehzadeh S, ShahAli S, Takamjani IE (2019) Application of ultrasonography in the assessment of abdominal and lumbar trunk muscle activity in participants with and without low back pain: a systematic review. J Manipulative Physiol Ther 42(7):541–550. https://doi.org/10.1016/j.jmpt.2019.05.003

    Article  Google Scholar 

  28. Eriksson M Crommert, Unsgaard‐Tøndel M, Vasseljen O (2017) Can sonography be used to estimate deep abdominal muscle activation in different static arm positions while standing? J Ultrasound Med 36(1):129–139. https://doi.org/10.7863/ultra.15.12057

    Article  Google Scholar 

  29. Zhou ZW, Siddiquee Rahman MM, Tajbakhsh N, Liang JM (2018) Unet++: a nested U-net architecture for medical image segmentation. In: Stoyanov D, Taylor Z, Carneiro G, Syeda-Mahmood T, Martel A, Maier-Hein L et al (eds) Deep learning in medical image analysis and multimodal learning for clinical decision support. 4th international workshop, DLMIA 2018, and 8th international workshop, ML-CDS 2018, held in conjunction with MICCAI 2018, Granada, Spain, September 2018. Lecture notes in computer science (Image processing, computer vision, pattern recognition, and graphics), vol 11045. Springer, Cham, pp 3–11. https://doi.org/10.1007/978-3-030-00889-5_1

  30. Ruan JC, Xie MY, Gao JS, Liu T, Fu YZ (2023) EGE-UNet: an efficient group enhanced unet for skin lesion segmentation. In: Greenspan H, Madabhushi A, Mousavi P, Salcudean S, Duncan J, Syeda-Mahmood T et al (eds) Medical image computing and computer assisted intervention - MICCAI 2023. 26th international conference, Vancouver, BC, Canada, October 2023. Lecture notes in computer science (MICCAI: international conference on medical image computing and computer-assisted intervention), vol 14223. Springer, Cham, pp 481–490. https://doi.org/10.1007/978-3-031-43901-8_46

  31. Ge Y, Cheng QM (2007) Boundary effect reduction in image filtering. GVIP J 7(2):17–25

    Google Scholar 

  32. LaPier A, Cleary K (2021) The influence of age and feedback training on ability to modulate upper extremity weight bearing force and pectoralis major muscle recruitment while following sternal precautions. Phys Ther Rehabil 8(1):1. https://doi.org/10.7243/2055-2386-8-1

    Article  Google Scholar 

  33. Valera-Calero JA, Fernández-De-las-peñas C, Varol U, Ortega-Santiago R, Gallego-Sendarrubias GM, Arias-Buría JL (2021) Ultrasound imaging as a visual biofeedback tool in Rehabilitation: an updated systematic review. Int J Environ Res Public Health 18(14):7554. https://doi.org/10.3390/ijerph18147554

    Article  Google Scholar 

  34. Kiesel KB, Uhl T, Underwood FB, Nitz AJ (2008) Rehabilitative ultrasound measurement of select trunk muscle activation during induced pain. Man Ther 13(2):132–138. https://doi.org/10.1016/j.math.2006.10.003

    Article  Google Scholar 

  35. Ravì D, Wong C, Lo B, Yang GZ (2017) A deep learning approach to on-node sensor data analytics for mobile or wearable devices. IEEE J Biomed Health Inform 21(1):56–64. https://doi.org/10.1109/JBHI.2016.2633287

Download references

Acknowledgements

The authors would like to thank all the subjects who voluntarily participated in this research. At the same time, we are very grateful for the research foundation established by Huang et al.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

SC, YL and HC all contributed to the research concept and study design, literature review, data analysis and interpretation, statistical analyses and manuscript writing; ZH contributed to the research concept and study design and data collection; YZ and YZ both contributed to the research concept and study design, data analysis and interpretation, statistical analyses and manuscript editing. All the authors have read and approved the final manuscript.

Corresponding authors

Correspondence to Yongjin Zhou or Yongping Zheng.

Ethics declarations

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cai, S., Lin, Y., Chen, H. et al. Automated analysis of pectoralis major thickness in pec-fly exercises: evolving from manual measurement to deep learning techniques. Vis. Comput. Ind. Biomed. Art 7, 8 (2024). https://doi.org/10.1186/s42492-024-00159-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s42492-024-00159-6

Keywords